QUALITY CONTROL
/ IPC-TM-650 Testing Method
/ MIL-STD-105 Selective Inspection
/ UL-796 Safety Standard for PCB
/ IPC-D-300 Size & tolerance Control
/ IPC-A600H II & III Class PCB Acceptance
/ IPC-6011/12 Performance & Capacity
/ IPC-4101 Base Material Quality Control
/ 8D-REPORT End-to-End Comprehensive control
Quality control | / IMC | / Flexible | / Standard | / HDI |
---|---|---|---|---|
AOI for all inner layers
|
Y -100%
|
Y -100%
|
Y -100%
|
Y -100%
|
Cross section
|
Y
|
Y
|
Y
|
Y
|
E-test (Fixture or Flying Probe)
|
Y
|
Y
|
Y
|
Y
|
High POT testing
|
Y -if needed
|
Y -if needed
|
Y -if needed
|
Y -if needed
|
Impedance control ±10%
|
Y
|
Y
|
Y
|
Y
|
Impedance control down to ±5%
|
Y
|
Y -if needed
|
Y
|
|
Humidity paper indicator
|
Y -if needed
|
Y -if needed
|
Y
|
Y
|
IPC A-600H
|
class 2
|
class 2 - 3
|
class 2 - 3
|
class 3
|
Outgoing test-report and COC
|
Y
|
Y
|
Y
|
Y
|
With Test Coupon
|
Y -if needed
|
Y -if needed
|
Y -if needed
|
Y -if needed
|